The FCU1310 is a portable service unit for the temporary measurement of particulate contamination, water saturation and fluid temperature in hydraulic systems. The integrated pump and the hoses included in the scope of delivery of the FCU 1000 series enable application on:
control circuits
pressure circuits and
depressurized containers

All measurement data (ISO, SAE/NAS and % saturation and temperature in ºC or ºF) are stored in files (measurement value file) and folders (measurement points) in the internal data memory. The data memory takes place with a time stamp. The evaluation can then be readily carried out on the PC in MS Excel or in HYDAC's own Fluid Monitoring software (FluMoS). For application in hydraulic systems, for the Service Department in the mobile hydraulics and for maintenance.

Suitable for hydraulic oils up to 350 mm²/s (hydraulic oils up to ISO VG 68)

For short-term operation (S4, in accordance with DIN EN 60034/VDE 0530)
Unit of Measure

Specifications

Short Description

N/A Si portable particle counter with Saturation and temp sensor

Contamination Code

N/A ISO 4406:1987; NAS 1638 or ISO 4406 1999, SAE AS 4059 (d)

Type

N/A Contamination/Saturation Sensor

Seal Material

N/A Viton

Weight

N/A 13.15 kg29 lb

Mounting

N/A Portable

Analog Interfaces

N/A Universal Serial Bus (USB)

Power Supply Voltage

N/A 115 VAC

Digital Interfaces

N/A Flumos mobile

Fluids

N/A Mineral Oil Based Hydraulic Fluids

Fluid Temperature Range [Min]

N/A 0 ºC32 ºF

Fluid Temperature Range [Max]

N/A 70 ºC160 ºF

Operation Pressure [Max] (Sensor Only)

N/A 345 bar5000 psi

Permissible Viscosity Range

N/A 350 cSt1600 SUS

IP Class

N/A IP67

Features

N/A Portable particle counter provides Particle counts and saturation sensor, integrated pump for testing pressureless reservoirs. Usable with Flumos light and Flumos mobile. Data is stored onboard and can be downloaded to a thumb drive.